Fusion Reactor | ATM10
|
Introduction The Fusion Reactor is Mekanism's end-game multiblock power generator capable of producing enormous amounts of energy through nuclear fusion. Unlike the Fission Reactor, the Fusion Reactor cannot melt down, making it one of the safest large-scale power generation methods available in All The Mods 10. This guide explains how to construct the reactor, understand the Reactor Controller, produce D-T Fuel, ignite the reaction, and maintain continuous power generation. |
Overview
The Fusion Reactor consumes D-T Fuel (Deuterium-Tritium Fuel) to sustain a fusion reaction. Once ignited, it continuously generates energy while fuel is supplied.
The reactor can operate in one of two modes:
- Passive Mode - Generates FE directly.
- Water-Cooled Mode - Produces Steam for an Industrial Turbine, resulting in significantly higher power output.
| Feature | Fusion Reactor |
|---|---|
| Meltdown Risk | None |
| Fuel Type | D-T Fuel |
| Power Output | Very High |
| Cooling Options | Passive or Water-Cooled |
| Ignition Required | Yes |
Required Components
Before constructing the Fusion Reactor, gather the following components.
| Component | Required | Purpose |
|---|---|---|
| Fusion Reactor Controller | ✔ | Controls the multiblock and displays reactor information. |
| Fusion Reactor Frame | ✔ | Forms the reactor casing. |
| Fusion Reactor Port | ✔ | Transfers fluids, gases and energy. |
| Laser Focus Matrix | ✔ | Required for laser ignition. |
| Fusion Reactor Logic Adapter | Optional | Provides automation and redstone control. |
Building the Reactor
Construct the multiblock structure exactly as shown in JEI. The interior of the reactor must remain completely hollow for the structure to form correctly.
Once construction is complete, right-click the Fusion Reactor Controller.
|
Information If the multiblock has been assembled correctly, the controller will display Structure Formed. If it reports Structure Incomplete, verify that:
|
Reactor Controller
The Reactor Controller provides access to all reactor information and settings. Right-click the Controller to open its interface.
Main Screen
The Main Screen displays the overall status of the Fusion Reactor.
- Structure status
- Charged Hohlraum slot
- Access to the Heat, Fuel and Statistics tabs
The text displayed at the top of the interface indicates whether the reactor structure is correctly assembled.
|
Important The Main Screen contains a single inventory slot. A Charged Hohlraum must be inserted into this slot before a laser can ignite the Fusion Reactor. |
Heat Tab
The Heat tab displays the reactor's operating temperatures and internal storage.
| Indicator | Description |
|---|---|
| Plasma Temperature | Current plasma temperature inside the reactor. |
| Case Temperature | Temperature of the reactor casing. |
| Internal Energy | Current FE stored within the reactor. |
| Water | Amount of water stored for cooling. |
| Steam | Steam currently stored inside the reactor. |
Fuel Tab
The Fuel tab displays the reactor's fuel supply and current Injection Rate.
| Tank | Contents |
|---|---|
| Left | Deuterium |
| Centre | D-T Fuel |
| Right | Tritium |
The reactor consumes Deuterium and Tritium at a rate equal to half of the current Injection Rate per tick.
Statistics Tab
The Statistics tab displays technical information about the reactor.
- Current Injection Rate
- Maximum Plasma Temperature
- Passive FE Generation
- Steam Production
This information is useful when monitoring reactor performance and tuning power output.




